sales@h2obreaker.com
Morgan Controls, Inc. 2006
Kennett Square, PA  19348
Tel: (610) 347-0102
H2OBreaker Specifications
* Supplied by 110 VAC to 12 VDC U.L. Approved adapter.


The valve, polymer or brass body, is a 2-way, internally-piloted, diaphragm valve that supplies a soft-closure when
activated to eliminate water hammer. The solenoid is a 12 VDC, bistable-latching type that is energized only when
cycled to close or open. The solenoid draws no power at any other time.

The Polyvinyl Chloride (PVC) and the Nylon 12 (Grilamid™ 12) fittings in the Water Flow Sensor Assembly meet the
specifications of the following tests:

Polyvinyl Chloride
ASTM D-1784 – Material Standard for Rigid Polyvinyl Chloride (PVC) Compounds
ASTM D-2464 – Threaded Polyvinyl Chloride (PVC) Plastic Pipe Fittings, Schedule 40.
ASTM D-2466 – Dimensional Specifications for Socket Polyvinyl Chloride (PVC) Plastic Pipe Fittings, Schedule 40.
ASTM D-2564 – Standard for PVC Solvent Cement
ASTM D-2855 – Standard for PVC Solvent Cementing Procedure
ASTM F-656   – Standard for Primers for PVC Solvent Cementing
MATERIAL      – Fittings are produced from PVC Type 1, Cell Classification 12454-B.
LISTINGS        – NSF (National Sanitation Foundation) for potable water services. Orlando, FL 32811

Nylon 12 (Grilamid™ 12)
ASTM D-638 -   Tensile Strength at Yield - 50 MPa
ASTM D-638 -   Tensile Strength at Break – 75 MPa
ASTM D-638 -   Elongation at Break  >50%
ISO 179/2 -        Notched Impact Strength – 8KJ/M2
ASTM D-3418 - Melting Point – 160
ºC
Water Main Dimension
3/4"
1"
1-1/4"
Flow Range [gallons/minute]
0.05 to 12
0.05 to 20
0.05 to 30
Temperature Range
35 to 120 ºF
35 to 120 ºF
35 to 120 ºF
Operating Pressure
150 psig
150 psig
150 psig
Power Supply *
12 VDC
12 VDC
12 VDC
Process Connections
NPT and slip
NPT and slip
NPT and slip